The Universal Industrial Transmitter
Product Details:
- Product Type The Universal Transmitter
- Color Black and Grey
- Weight 540 Grams (g)
- Voltage 15-40 Volt (v)
- Material ABS
- Type Electronic
- Temperature Range 100-200 Celsius (oC)
- Click to View more
The Universal Industrial Transmitter Price And Quantity
- 6000.00 - 35000.00 INR
- 1 Piece
The Universal Industrial Transmitter Product Specifications
- Electronic
- Black and Grey
- 100-200 Celsius (oC)
- The Universal Transmitter
- ABS
- 15-40 Volt (v)
- 540 Grams (g)
The Universal Industrial Transmitter Trade Information
- Cash Advance (CA) Cash in Advance (CID)
- 100 Piece Per Week
- 3 Days
- Yes
- Sample costs shipping and taxes has to be paid by the buyer
- All India
Product Description
Problem-free, accurate humidity measurement results from the most stable sensor in the industry combined with our unique HygroClip digital probe technology, designed to practically eliminate any maintenance downtime. When it is time for a scheduled calibration hot swap in seconds with a calibrated probe without loss of measurement accuracy. HygroFlex8 transmitters provide superb precision and state-of-the-art functionality, taking humidity and temperature measurement to a whole new level of performance and reliability (0.8 %rh and < 0.1oC accuracy).
Innovation In Humidity And Temperature Measurement
- Highest accuracy at 0.8 %rh and 0.1oC
- Outstanding long-term stability and chemical resistance
- Widest Temperature measuring range at -100200 oC
- Two Interchangeable HygroClip digital or analog probe inputs
- 10,000 point data logging with time stamp and battery back-up
- Up to 4 programmable Analog Outputs available
- Digital Output Options
- Multiple Alarm Relays
- Audible and Visual Alarms
- Galvanically Isolated power supply
AirChip3000 Digital Technology - The latest generation of ROTRONIC probes and instruments use the AirChip 3000 technology with features such as:
- Compensates humidity and temperature over 30,000 reference points
- Dew/frost point calculation
- Sensor auto-diagnostics and automatic correction
- Active alarming and information
- User congurable xed output signals
- Conforms to FDA21 CFR Part 11 and GAMP4 ( audit trail)
Optional display :
- The clear, backlit graphic display is easy to read and the simple menu navigation provides fast access to all the information available
- Trend indication of values
- Display resolution to 2 decimal places
- Calculates and Displays Delta Value between the two probes
- Three programmable display formats
Flexible choice of probes :
- The HygroFlex 8 can be tted with TWO interchangeable
- HygroClip2 probes
- Compatible with all HygroClip2 probe types
- Connection of two analog probes
- Changing of HygroClip2 probes requires no further adjustment
- Use of probe simulators allows easy process validation
Output signals :
- Four freely selectable and scalable analog outputs
- Freely selectable output type through HW4 software: 0/420 mA; 01/5/10 VDC
- Optional digital outputs allow integration on a network via Ethernet or RS-485
- Combined digital and analogue output signals, allow controlling and steering a device with one transmitter
Data logging function :
- Logs up to 10,000 value pairs, relative humidity and temperature provided by a single HygroClip2 probe
- Logs up to 10,000 data values provided by a single 1-channel analog probe
- Both probe inputs can be logged at the same time
- Each record is date and time stamped (real-time clock)
Relay output :
- Up to 4 relays
- Each relay can be programmed individually
- Each relay can be set to control any measured or calculated parameter
Alarm function :
- Visible and audible alarm can be programmed when the HF8 detects the following:
- Out-of-limits value (dened with the HW4) for each probe input
- Communication loss with the probe
- Impaired rh sensor or major sensor failure
Applications :
The HygroFlex8-series is ideal for all applications where exact measurement of humidity and temperature is of decisive importance, for example the food and pharmaceutical industries, printing and paper industries, meteorology, agricultural sector, archaeology and climatology. There is hardly a eld today in which these parameters may be ignored. It is ultimately the measuring task at hand that denes the combination of transmitter and probe that best covers your needs
Probes For Hygroflex Transmitters. :
Whether you need a more sophisticated industrial probe to measure in a high temperature range or a standard Hygroclip2 probe to measure ambient conditions, we can provide you with the ideal HygroClip2 probe to suit your requirements. All HygroClip2 probes can be individually calibrated and adjusted to increase measurement precision where you need it the most. This capability is exactly what makes every probe in the product range a high-end solution for your application.
Industrial Probes in general
Probes for process applications. (xed installation)
- Operating range: 0100 %rh, -100200 oC (-148392 oF)
- Pressure: HC2-IE Series: 0400 bar (05,800 PSI)
- Probe diameter: 15 mm; 25/15 mm, NPT 1/2" or G 1/2" thread
HC2-IC Series
- Humidity measuring range: 0100 %rh
- Temperature limits at sensor: -100200 oC
- Barrel: PPS
- Barrel diameter: 15 or 25/15mm
- Barrel length: 100/250/400/550/700 mm
- Probe cable length.: 2 m or 5 m
HC2-IM Series
- Humidity measuring range: 0100 %rh
- Temperature limits at sensor: -100200 oC
- Barrel: Stainless steel
- Barrel diameter: 15 or 25/15 mm
- Barrel length: 120/280/430/580 mm
- Probe cable length.: 2 m or 5 m
HC2-IE Series
- Humidity measuring range: 0100 %rh
- Temperature limits at sensor: -100200 oC
- Barrel: Stainless steel NPT 1/2" or
- G 1/2" thread for maximum 400 bar
- Probe cable length.: 2 m or 5 m
- Standard Probe
- Humidity measuring range: 0100 %rh
- Temperature limits -50100 oC (-58212 oF)
- Diameter: 15 mm (0.6"), length: 85 mm (3.3")
- Housing and lter cap: polycarbonate, black
Technical Specification :
Device type | Humidity temperature transmitter with analog output signals relay outputs |
Circuit type | 3-wire |
Number of probe inputs | 2 (digital or analog) |
Digital probe | HygroClip 2 probe |
Analog probe (12-bit AD converter) | Supply voltage to probe: 5 VDC Maximum probe signal range: 0 to 3.3 VC Congurable measuring range and measurement unit |
Probe type | All HC2 probes (digital) |
Accuracy at 23 +5 oC | +0.8 %rh / 0.1 C (typically value), Depends on the probe |
Measurement range | -100200 oC / 0100 %rh, probe dependent |
Psychrometric calculations | Dew point (Dp) above and below freezing |
Start-up time | 1.9 s (typical) |
Data refresh rate | 1 s (typical) |
Supply voltage HF83x | 1540 VDC or 1228 VAC, 50-60 Hz |
Supply voltage HF84x | 9-36 VDC, with galvanic isolation |
Supply voltage HF86x | 85265 VAC, 5 Watt, 50-60 Hz with galvanic isolation |
Analogue output 1, 2, 3 and 4 | Analogue output signals, scalable by user |
Interface options | RS-485 and analogue output Ethernet (wired) |
Relay 1, 2, 3 and 4 | Can be made to correspond to any parameter and probe |
Parameter, Operation | User congurable with the ROTRONIC HW4 software |
Relay type | SPDT (single pole double throw) |
Optional display | LC, 1 or 2 decimals resolution backlight, trend and alarm indication |
Housing material / Weight | ABS / 540 g (1 lb 3 oz) - depends on model |
Housing protection grade | IP 65 (except models with USB or Ethernet interface) |
Storage and transit | -50+70 oC / -20...+70 oC (models with display) |
Operating limits at electronics | -40 +85 oC / -10.60 oC (models with display) |
Temperature limits at probe | Depends on probe model |
Maximum humidity at sensor | 100 %rh up to 80 oC (176 oF) |
CE / EMC immunity | EMC Directive 2004/108/EG: |
Solder type | Lead free (RoHS directive) |
Fire protection class | Corresponds to UL94-HB |
FDA / GAMP directives | Compatible |