Back to top
08045478718
Change Language
Send SMS    Call Me Free Send Inquiry
                        Transmitters for Moisture Content in Oil

                        Transmitters for Moisture Content in Oil

                        50000.00 - 150000.00 INR

                        Product Details:

                        • Usage For Moisture Content In Oil
                        • Color Black, Silver and Grey
                        • Material Metal and Plastic
                        • Accuracy + 0.01-+ 0.02 %
                        • Pressure 15-145 PSI
                        • Voltage 8-35 Volt (v)
                        • Click to View more
                        X

                        Transmitters for Moisture Content in Oil Price And Quantity

                        • 50000.00 - 150000.00 INR
                        • 1 Piece

                        Transmitters for Moisture Content in Oil Product Specifications

                        • 15-145 PSI
                        • + 0.01-+ 0.02 %
                        • 8-35 Volt (v)
                        • For Moisture Content In Oil
                        • Metal and Plastic
                        • Black, Silver and Grey

                        Transmitters for Moisture Content in Oil Trade Information

                        • Cash Advance (CA) Cash in Advance (CID)
                        • 100 Piece Per Week
                        • 3 Days
                        • Yes
                        • Sample costs shipping and taxes has to be paid by the buyer
                        • All India

                        Product Description

                        Owing to rich field knowledge as well as professional workforce, we have achieved a noted position as a leading exporter and importer of Transmitters for Moisture Content in Oil. Provided transmitter finds its application in several industries for detection of moisture in insulation and lubrication oil. Accessible in variety of technical specifications to meet patrons specific requirements and needs, these transmitters for moisture content in oil are developed using sophisticated technology in tune with set international parameters. 

                        Technical Specification :

                        Water activity sensor1)

                        HC1000-400

                        Measuring range1)

                        0...1aw

                        Accuracy incl. hysteresis and nonlinearity in air
                        - Special calibration against certified standards
                        - Standard calibration

                        + 0.01aw (0...0.9aw) + 0.02aw (0.9...1aw)
                        +
                        0.02aw (0...0.9aw) + 0.03aw (0.9...1aw)

                        Temperature dependence of electronics

                        typ. + 0.0001 [1/oC] (typ. + 5.6 * 10-5 [1/oF])

                        Temperature dependence of sensing probe

                        typ. + (0.00002 + 0.0002 x aw) x T [oC] T = T - 20oC

                        Response time with stainless steel filter at 20oC / t90

                        typ. 10min in still oil

                        Temperature

                        Temperature sensor element

                        Pt1000 (tolerance class A, DIN EN 60751)

                        Working range sensing probe

                        -40...180oC (-40...356oF)

                        Temperature dependence of electronics

                        typ. + 0.005oC/oC

                        Outputs


                        Two freely selectable and scaleable analogue outputs

                        0 - 5V
                        0 - 10V
                        4 - 20mA
                        0 - 20mA

                        -1mA < IL < 1mA
                        -1mA < IL < 1mA
                        RL < 500 Ohm
                        RL < 500 Ohm

                        Adjustable measurement range


                        Water activity

                        from up to units
                                 aw   01

                        Temperature

                        T -40 (-40) 180 (356) oC (oF)

                        Water content 3)

                        x 0 1000 ppm

                        General

                        Supply voltage

                        SELV 8...35V DC SELV = Safety Extra Low Voltage
                        SELV 12...30V AC (optional 100...240V AC, 50/60Hz)

                        Current consumption :
                        - 2x voltage output
                        - 2x current output

                        for 24V DC/AC:

                        typ. 40mA
                        typ. 80mA

                        Pressure range sensing pobe

                        0.01...10bar (0.15...145psi)

                        System requirements for software

                        WINDOWS 98 or later; serial interface

                        Serial interface for configuration 4)

                        RS232C

                        Housing / Protection class

                        PC or Al Si 9 Cu 3 / IP65; Nema 4

                        Cable gland

                        M16 x 1.5 cable 4.5 - 10 mm (0.18 - 0.39")

                        Electrical connection

                        screw terminals up to max. 1.5mm (AWG 16)

                        Sensor protection

                        stainless steel filter

                        Operating temperature range of electronics

                        -40...60oC (-40...140oF)

                        Working and storage temperature range Housing with display

                        -20...50oC (-4...122oF)

                        Storage temperature

                        -40...60oC (-40...140oF)

                        Electromagnetic compatibility according to

                        EN61000-6-2 EN 61000-6-3

                        ICES-003 ClassB

                        EN 61326-1+A1+A2

                        FCC Part15 ClassB

                        Options

                        Display

                        graphical LCD (128x32 pixels), with integrated push- buttons for selecting parameters and MIN/MAX function

                        Alarm outputs

                        2 x 1 switch contact: 250V AC / 6A and 28V DC / 6A threshold + hysteresis can be adjusted with configuration software

                        Switching parameters (freely selectable)

                        aw Water activity
                        T Temperature
                        x Water content

                        Enter Buying Requirement Details
                        Email Id
                        Mobile number

                        Other Products in 'Industrial Sensors' category