Industrial Transmitter for Dew Point Measurement
Product Details:
- Test Range 60 to 60 Degree C Td
- Application For Monitoring of Air Pressure Pipelines
- Power Supply 8-35V DC 12-0V AC
- Weight 200-500 Grams (g)
- Material Metal and Plastic
- Product Type Industrial Transmitter
- Color White and Grey
- Click to View more
Industrial Transmitter for Dew Point Measurement Price And Quantity
- 1 Piece
- 25000.00 - 60000.00 INR
Industrial Transmitter for Dew Point Measurement Product Specifications
- For Monitoring of Air Pressure Pipelines
- 60 to 60 Degree C Td
- 8-35V DC 12-0V AC
- 200-500 Grams (g)
- Industrial Transmitter
- Metal and Plastic
- White and Grey
Industrial Transmitter for Dew Point Measurement Trade Information
- Cash in Advance (CID) Cash Advance (CA)
- 100 Piece Per Week
- 3 Days
- Yes
- Sample costs shipping and taxes has to be paid by the buyer
- All India
Product Description
Exact dew point monitoring is increasingly playing a more important role in many industrial applications, such as drying processes, air pressure pipelines, etc. For these purposes the multifunctional EE35 Series offers the ideal features. The EE35 Series is based on a functional, user-friendly housing concept and on the proven polymer humidity sensors of the HC Series. A specially developed autocalibration process enables measurements in a measurement range of -60...60oC Td (-76...140oF Td), with a Td measurement accuracy of +2oC (+3.6oF). Two freely configurable and scaleable analogueoutputs are available for the two measurement values (Td, T). An optional hygrostat output, which can be set by means of a potentiometer, provides an alarm signal in a simple way when a threshold of the permitted dew point is exceeded. An optional display for the measurement values and the associated MIN/MAX values allows a quick overview of the current situation.
Auto calibration
Dew points in the range of -60...-20oC (-76...-4oF) at room temperatures correspond to relative humidity values of 0.08...5.37% RH. The measurement of such low humidity values is not possible with conventional capacitive measurement methods. For the EE35 Series, a special auto-calibration process is used to compensate for the usual drift effects and thus to achieve high accuracy measurements also at -60oC Td (-76oF Td).
Installation
In addition to the direct mounting of the dew point probe, a ball valve installation enables the mounting and removal of the probe without having to interrupt the running process.
Alarm Output
An optional alarm module with one relay output is available for control and alarm purposes. The setting of the Td threshold can be easily done with the potentiometer on the printed circuit board.
Integrated power supply
A power supply, integrated in the back module of the housing, can be ordered optionally (100...240V AC, 50/60Hz; ordering code V01). The power supply V01 is available for both polycarbonate and metal housing and comes standard with two plugs for supply and outputs to allow an easy connection.
Typical Applications :
- Industrial processes
- Monitoring of air pressure pipelines
- Warehouses
- Drying processes
- Paper industries
- Chemical industries
Features :
- Measuring range -60...60oC Td (-76...140oF Td)
- Accuracy of measurement +2oC Td (+3.6oF Td)
- Traceable calibration alarm output for dew point
- Auto-calibration
Humidity sensor | HC1000-400 |
Measuring range (below 0oC / 32oF the transmitter outputs frostpoint) | standard calibration: -40...60oC (-40...140oF) |
Accuracy | +2oC ( + 3.6oF) |
Response time t90 | 80 sec. -20oC -40oC (-4oF -40oF) |
Temperature |
|
Sensor | Pt1000 DIN A |
Measuring range | 0...60oC (32...140oF) |
Accuracy of temperature measurement at 20C (68F) | +0.2oC (+0.36oF) |
Sensitivity error at full scale | +0.1oC (+0.18oF) |
Temperature dependence of electronics | < 0.005oC/oC |
Outputs | |
Two freely selectable and scaleable analogue outputs | 0 - 5V |
General | |
Supply voltage | 8...35V DC |
Current consumption : | typ. 40mA, with autocalibration: 100mA |
Pressure range | 0...10bar (0...145psi) |
Housing / protection class | PC or Al Si 9 Cu 3 / IP65; Nema 4 |
Cable gland | M16 x 1.5 (option: plug)cable 4.5 - 10 mm (0.18 - 0.39") |
Electrical connection | screw terminals up to max. 1.5mm (AWG 16) |
Sensor protection | stainless steel sintered filter |
Working temperature range | Probe: -40...60oC (-40...140oF) |
Storage temperature range | -40...60oC (-40...140oF) |
Electromagnetic compatibility according to | EN61326-1:1997 + note1:1998 |
Technical Data f or Options | |
Display | graphical LC display (128x32 pixels), with integrated push- buttons for selecting parameters Td or T and MIN/MAX functions |
Alarm output for Td/Tf | - range: -60...40oC Td (-60...40oF Td) adjustable with the potentiometer on the printed circuit board |