                        Carbon Dioxide Transmitter

                        Carbon Dioxide Transmitter

                        6000.00 - 30000.00 INR

                        Product Details:

                        • Material ABS
                        • Product Type Display Transmitter
                        • Power DC Volt (v)
                        • Voltage 24 Volt (v)
                        • Type Electronic
                        • Temperature Range 0 to +50 Celsius (oC)
                        • Click to View more
                        X

                        Carbon Dioxide Transmitter Price And Quantity

                        • 1 Piece
                        • 6000.00 - 30000.00 INR

                        Carbon Dioxide Transmitter Product Specifications

                        • 0 to +50 Celsius (oC)
                        • 24 Volt (v)
                        • DC Volt (v)
                        • Display Transmitter
                        • ABS
                        • Electronic

                        Carbon Dioxide Transmitter Trade Information

                        • Cash in Advance (CID) Cash Advance (CA)
                        • 100 Piece Per Week
                        • 3 Days
                        • Yes
                        • Sample costs shipping and taxes has to be paid by the buyer
                        • All India

                        Product Description

                        As a quality-oriented organization, we are focused to give our customers excellent quality Carbon Dioxide Transmitter. It is a new simple, low cost, state-ofthe-art, infrared and maintenance-free carbon dioxide transmitter for installation in the climate zone or in the ventilation duct. This measures the carbon dioxide concentration in the ambient air up to 2000 ppm and transforms the data into an analogue output. Also, before providing to our clients Carbon Dioxide Transmitter is thoroughly checked on several quality parameters by our skilled quality checkers assuring its flawlessness.

                        Features :

                        • SenseAir's patented state-of-the-art gold-plated infrared (NDIR) waveguide technology offers reliable measurements
                        • Measurement range: 0 - 2 000 ppm CO2
                        • Two analogue outputs (not model -I):
                        • Internal automatic self-diagnostics.
                        • Maintenance-free in normal applications
                        • Cost-optimized for connection to DDC:s
                        • Prepared for complementary passive temperature element (model -Tr).
                        • Different housing options

                        Applications :

                        • eSENSETM is an extremely cost-optimized sensor solution for climate control of buildings and other processes.
                        • By controlling the ventilation based on actual demand, it helps you decrease your energy consumption and yet have a healthy indoor climate!
                        • The different housing options makes the eSENSETM available to almost any application or environment for example in greenhouses, residential and commercial buildings.
                        • eSENSETM -Tr is also prepared for quick mounting of a complementary passive temperature element, which can easily be done by the customer.
                        • eSENSETMII has a new housing that fits directly on top of EU and US electrical junction box standards

                        Specification :

                        General Performance

                        Compliance with

                        EMC directive 89/336/EEC. RoHS directive 2002/95/EG

                        Operating Temperature Range

                        0 - 50oC

                        Storage Temperature Range

                        -40 to +70 oC (display model -D: -20 to +70 oC )

                        Operating Humidity Range

                        0 to 95% RH (non-condensing)

                        Operating Environment

                        residential, commercial and industrial spaces 1

                        Warm-up Time

                        1 min. (@ full specs 15 minutes)

                        Sensor Life Expectancy

                        > 15 years

                        Maintenance Interval

                        no maintenance required 2

                        Self Diagnostics

                        complete function-check, LCD error indication (display model -D)

                        Display (model -D)

                        4 Digits, 7 segments LCD with ppm indicator

                        Electrical

                        Power Input

                        24 VAC/VDC +20%, 50 Hz (half-wave rectifier input)

                        Power Consumption .

                        < 1 Watt average

                        Connection screw terminal A .

                        4 x 1,5 mm2 for power input (G+, G0) and voltage outputs (OUT1, OUT2)

                        Connection screw terminal B .

                        2 x 1,5 mm2 for passive resistive output (Y, M) for option -Tr

                        Model IP50

                        34 cm 3-wire pigtail. Please note that OUT2 is not made available.

                        CO2 Measurement

                        Sensing method .

                        Gold-plated infrared (NDIR) waveguide technology with Automatic Background Calibration (ABC) and passive gas diffusion (no moving parts)

                        Response Time (T1/e)

                        < 10 sec. @ 30 cc/min. flow rate , < 3 min. diffusion time

                        Repeatability .

                        + 20 ppm + 1 % of reading

                        Accuracy 2

                        + 30 ppm + 3 % of reading

                        Annual Zero Drift 2

                        < + 10 ppm

                        Pressure Dependence

                        + 1.6 % reading per kPa

                        Measurement range

                        0 - 3 000 ppm

                        Outputs

                        Output signal terminal CO23


                        OUT1 linear conversion range

                        0 - 10 VDC for 0 - 2 000 ppm.

                        OUT2 linear conversion range

                        2 - 10 VDC, or 4 - 20 mA for 0 - 2 000 ppm.
                        D/A resolution 10 bits, 10 mV

                        D/A conversion accuracy

                        + 2 % of reading + 50 mV

                        Electrical characteristics

                        ROUT < 100 Ohm, RLOAD > 5 kOhm

                        Resistive terminals 4

                        Thermistor outputs

                        temperature measurement resistor terminal output with signal return connected to ground terminal (option -Tr)