Back to top
08045478718
Change Language
Send SMS    Call Me Free Send Inquiry
                        HygroFlex 5 Series

                        HygroFlex 5 Series

                        6000.00 - 35000.00 INR

                        Product Details:

                        • Weight 100-500 Grams (g)
                        • Voltage 10-28 Volt (v)
                        • Product Type Transmitter
                        • Material Metal
                        • Usage For HVAC Applications, Building Management Systems, Museums and Libraries
                        • Type Electronic
                        • Click to View more
                        X

                        HygroFlex 5 Series Price And Quantity

                        • 1 Piece
                        • 6000.00 - 35000.00 INR

                        HygroFlex 5 Series Product Specifications

                        • 10-28 Volt (v)
                        • Transmitter
                        • Metal
                        • For HVAC Applications, Building Management Systems, Museums and Libraries
                        • Electronic
                        • 100-500 Grams (g)

                        HygroFlex 5 Series Trade Information

                        • Cash in Advance (CID) Cash Advance (CA)
                        • 100 Piece Per Week
                        • 3 Days
                        • Yes
                        • Sample costs shipping and taxes has to be paid by the buyer
                        • All India

                        Product Description

                        The HygroFlex5 Series offers you ultimate performance and flexibility thanks to its interchangeable HygroClip2 probes. The transmitters come in wall and duct mount versions. Many useful functions can be accessed with optional HW4 software. HF5-Series is available with analog and digital outputs, so compatibilty with almost any monitoring or control system is assured. Digital versions may be networked togther to form a dedicated environmental monitoring system using HW4 software. The new generation device not only has a unique calibration and adjustment process, but also allows probes to be interchanged in just a few seconds. This easy interchangeability during operation reduces down-time and service costs to a huge extent. The possibility of using every probe as a simulator with fixed output values is a big advantage for system validation. In the case of networked devices this can even be carried out online from a remote PC workstation.

                        Applications

                        • High specification HVAC applications, building management systems, museums, libraries, environmental monitoring systems.

                        Highlights :

                        • Unique calibration and adjustment process
                        • Highest reproducibility
                        • Wall and duct versions; the wall version also serves for the connection of cable based probes
                        • Many useful functions can be activated with the optional HW4 software

                        HF5 wall & duct versions

                        Applications

                        • HVAC applications, building management systems, museums, libraries, etc.

                        Highlights and common features

                        • Probe interchangeable in just a few seconds
                        • Measures relative humidity, temperature and dew/frost point
                        • Calculates all psychrometric values
                        • Range of application -4060 oC; -1060oC with LCD, 0100 %rh
                        • Automatic sensor test & drift compensation
                        • Use as a simulator for system validation
                        • UART service interface
                        • Precision: dependent on the probe and adjustment profile used
                        • Can be mounted on a DIN rail (see accessories, page 102)
                        • Suitable probes: all HygroClip2 (HC2x) probes

                        Includes flange for duct mounting :

                        Wall version

                        HF52-W series

                        HF53-W series

                        Type

                        2- or 2 x 2-wire

                        3/4-wire

                        Signals

                        Signals freely scalable

                        Signals freely selectable and scalable

                        Features

                        Alarm indicators, display and keypad (optional) Optional USB & RS485 interface


                        Duct version

                        HF52-D series

                        HF53x-D series

                        Type

                        2- or 2 x 2-wire

                        3/4-wire

                        Signals

                        Signals freely scalable

                        Signals freely selectable and scalable

                        Features

                        Alarm indicators, display and keypad (optional) Optional USB & RS485 interface

                        Technical Specification :

                        Power supply / Connections

                        HF52

                        HF53

                        Supply voltage

                        1028 VDC, 420 mA current loop
                        V min = 10 V + (0.02 x load*)

                        1540 VDC /1228 VAC
                        at 500

                        Current consumption

                        2 x 20 mA

                        <50 mA

                        Electrical connections

                        Screw terminals and M16 cable gland or 1/2" conduit adapter

                        Humidity measurement

                        HF52

                        HF53

                        Sensor

                        ROTRONICHygromerIN-1 (depending on the HygroClip2 used)

                        Measurement range

                        0100 %rh

                        Accuracy at 23 oC

                        + 0.8 %rh (probe dependent)

                        Repeatability

                        0.3 %rh

                        Long term stability

                        <1 %rh/year

                        Response time

                        Typically 10 s for 63 % of a jump 35 - 80 %rh (1 m/sec air flow at sensor)

                        Temperature measurement

                        HF52

                        HF53

                        Sensor

                        Pt100 1/3 Class B (in all HygroClip2 probes)

                        Measurement range

                        -100200 oC / -148392 oF

                        Accuracy at 23 oC

                        +0.1 K (probe dependent)

                        Repeatability

                        0.05 oC

                        Long term stability

                        <1 oC/year

                        Response time

                        Typically 4 s for 63 % of a change from 23 to 80 oC (1 m/sec air flow at sensor)

                        Calculated parameters

                        HF52

                        HF53

                        Psychrometric calculations

                        All types available

                        Start-up time

                        Typically 3.4 s

                        Typically 1.9 s

                        Signal type (selectable by jumper)

                        420 mA

                        020 mA, 420 mA , 01 V, 0 5 V, 010 V

                        Scale limits

                        -999.99+9999.99 units, user scaleable

                        Maximum load (in )

                        0/500

                        0/500 (current signal), min. 1000 (voltage signal)

                        Type of interface

                        USB or Ethernet TCP/IP (cable connection or wireless) & RS485

                        Service interface

                        UART (universal asynchronous receiver transmitter) on mini USB connector

                        Service cable maximum length

                        5 m (16.4 ft)

                        Optional display

                        LCD, 1 or 2 decimals, without backlight

                        LCD, 1 or 2 decimals, with backlight and trend indicator

                        Probe material

                        Polycarbonate

                        Filter material

                        Polyethylene

                        Housing material / Protection

                        ABS / IP 65 (except for models with USB interface)

                        Weight

                        Approx. 250 g

                        CE/EMC compatibility

                        EMC Directive 2004/108/EC

                        EN 61000-6-1: 2001, EN 61000-6-2: 2005

                        EN 61000-6-3: 2005, EN 61000-6-4: 2001 + A11

                        Solder

                        Lead free (RoHS-compliant)

                        Fire resistance

                        Conforms to UL94-HB

                        FDA/GAMP compatibility

                        Conforms to FDA 21CFR Part 11 and GAMP4

                        Electronics operating range

                        -4060oC / (models with display: -1060 oC) 0100 %rh, non-condensing

                        Maximum wind velocity at probe

                        40 m/s (7,870 ft/min)

                        Enter Buying Requirement Details